Anern Solar Inverter- 8200W 10200W on and off Grid Hybrid MPPT 160A 180A 230V Pure Sine Wave DC 48V
Special Order
Anern Solar Inverter- 8200W 10200W on and off Grid Hybrid MPPT 160A 180A 230V Pure Sine Wave DC 48V
Connectable battery type: Lead-acid/Lithium iron phosphate(LiFePO4)/colloid/lithium battery
Waveform:Pure Sine Wave
10200W:Dual PV Input(Dual MPPT),Dual AC Output(Only MAX10200W models dual MPPT)
Model |
SCI-MAX-8200/EVO-8200 |
SCI-MAX-10200 |
RATED POWER |
8200W
|
10200W |
Maximum PV Input Power |
8200W
|
10800W |
GRID-TIED OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
MPPT DC Voltage Range |
90-450VDC |
Number of MPPT Trackers/Maximum
Input Current
|
1/27A
|
2/18A
|
GRID OUTPUT (AC) |
Nominal AC Output Voltage |
220/230/240VAC |
AC Output Voltage Range |
195.5-253VAC |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
Nominal Output Current
|
35.6A
|
44.3A
|
EFFICIENCY |
Maximum Conversion Efficiency (Solar to AC) |
98% |
TWO LOADS OUTPUT POWER |
Full Load |
8200W
|
10200W |
Maximum Main Load |
8200W
|
10200W |
Maximum Second Load (battery mode)(Only if the battery voltage is below 44V) |
2733W
|
3400W |
Main Load Cut Off Voltage |
44VDC
|
44VDC |
Main Load Return Voltage |
48VDC
|
48VDC |
OFF-GRID OPERATION |
AC Start-up Voltage/Auto Restart Voltage
|
120-140VAC/180VAC
|
Acceptable Input Voltage Range
|
90-280VAC or 170-280VAC
|
Maximum AC Input Current
|
40A
|
50A
|
Nominal Operating Frequency
|
50/60Hz
|
Surge Power
|
16400W
|
20400W
|
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
BATTERY & CHARGER |
Nominal DC Voltage |
48VDC
|
48VDC |
Maximum Charging Current(Solar to AC) |
160A
|
160A |
Maximum AC Charging Current |
140A
|
160A |
GENERAL |
Communication interface |
WIFI |
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
–10°C - 50°C |
Storage Temperature |
–15°C - 60°C |










Expro 8200W 10200W:Dual PV Input(One MPPT),Dual AC Output
Model |
EX-Pro-8200 |
EX-Pro-10200 |
Maximum PV Input Power |
8200W |
10200W |
Rated Output Power |
8200W |
10200W |
Maximum Solar Charging Current |
160A |
160A |
GRID-TIE OPERATION |
PV Input(DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
Maximum DC Voltage |
500VDC |
MPPT Voltage Range |
90V-450VDC |
Number of MPPT Trackers/Maximum Input Current |
1/27A |
Grid Output(AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Voltage Range |
195-253VAC |
Nominal Output Current |
35.6A |
44.3A |
Efficiency (Peak) Battery to INV. |
94% |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz/59-61±1Hz |
Two Load Output Power |
Full Load |
8200W |
10200W |
Maximum Main Load |
8200W |
10200W |
Maximum Second Load(battery mode)(Only if the battery voltage is below 44V) |
2733W |
3400W |
Main Load Cut Off Voltage |
44VDC |
44VDC |
Main Load Return Voltage |
48VDC |
48VDC |
OFF-GRID OPERATION |
AC Input |
AC Start-up Voltage/Auto Restart Voltage |
120-140VAC/180VAC |
Acceptable Input Voltage Range |
90-280VAC or 170-280VAC |
Maximum AC Input Current |
40A |
50A |
Nominal Operating Frequency |
Surge Power |
16400W |
20400W |
Battery Mode Output |
Nominal Output Voltage |
48VDC |
48VDC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
Battery & Charger |
Nominal DC Voltage |
48VDC |
48VDC |
Maximum Solar Charging Current |
160A |
160A |
Maximum AC Charging Current |
140A |
140A |
PHYSICAL |
Dimension, D x W x H (mm) |
537*390*130mm |
Communication interface |
WIFI |









Q:Can it directly supply power to the load?
A:YES
Q:Can it be connected to the grid?
A:PV gives priority to power supply to the load, and extra to charge the battery, and more can be integrated into the grid (need to be based on local government policies)(1600W and 3000W models cannot send remaining power)
Q: How many solar panels need to be connected?
A: In order to start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, The maximum does not exceed 500V. For PRO-3.6KW/PLUS-6.2KW, and the power of the solar panel is not more than 6.2KW/6.5KW. For example, 10 pcs of 250W 30V solar panels are connected in series.
Q: Can inverters be connected in series or parallel?
A: NO.
Q: Is this a on grid-tied inverter? Can it be output to utility?
A: YES. It is a hybrid inverter that can be both off-grid and on-grid connected(Except 1600W and 3000W.1600W and 3000W Off grid only)
Q: Does the inverter have to be connected to the battery?
A: 3600W 6200W 8200W 10200W can be connected with or without battery, but without the battery, the voltage of the solar panel should exceed 360Vdc.
Q: What types of batteries can be used?
A: Lead-acid batteries, gel batteries,Lithium Iron Phosphate(LiFePo4) and lithium batteries can be used. 24V battery for 3.6KW, 48V battery for 6.2KW. The battery cannot be less than 100AH.
Q: Can it be used in air conditioners, water pumps, and wind turbines?
A: It can be used in air conditioners, but not in water pumps and wind turbines.
Q: Is it a high frequency inverter or a low frequency inverter?
A: High frequency
Q: Can the utility be used to power the inverter when there is no sun?
A: YES.
Q: How to choose the power of the inverter according to the household appliances?
A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter is at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
Q: Is it possible to use PV, battery, grid supply at the same time?
A: YES. The default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.

Shipping
Items marked FREE SHIPPING on the product page will ship for FREE !
In order to keep costs down and our pricing simple, we either provide free shipping or, in certain cases, charge shipping per item. This charge, if any, is indicated in your shopping cart and covers ground shipping within the contiguous United States.
We will not surprise you with hidden charges or handling fees. The price you see in the shopping cart is the price you pay - with one exception: if you are shipping an order to a state that collects Sales Tax Exclusive, we are required to charge sales tax....Read More.
Return Policy
PowerSupplyUSA offers a 30-day Satisfaction Guarantee on all purchases, unless otherwise indicated in product details. You can return most items for a Refund or Store Credit within 30 days of delivery. Clients wishing to return a purchase, must follow the Product Return procedures detailed below.
To be eligible for a Return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.... Read More.